Novo

Instantânea Thermal Unit STUTTGART

Digital control board, Cast iron body, Available with powers of 25, 32 and 40kW. The range is divided into three versions:
- STUTTGART-A - For Central Heating and Instant Hot Water - Exchanger;
- STUTTGART-AC - For Central Heating and DWH by external accumulation - 2 circulating pumps;
- STUTTGART-C - Only for Central Heating - 1 circulator pump.
There are also each one of the previous versions with combustion air supply model

Ficha técnica do produto
Código Modelo Preço (s/IVA) Disponibilidade Comprar
0101-0401 Thermal Unit STUTTGART 25-A
0101-0402 Thermal Unit STUTTGART 25-AC
0101-0405 Thermal Unit STUTTGART 32-A
0101-0406 Thermal Unit STUTTGART 32-AC
0101-0409 Thermal Unit STUTTGART 40-A
0101-0410 Thermal Unit STUTTGART 40-AC
0101-0413 Thermal Unit STUTTGART 25-C
0101-0415 Thermal Unit STUTTGART 32-C
0101-0417 Thermal Unit STUTTGART 40-C

Principais Características


- Digital control board;
- Cast iron elements;
- 3 smoke passageways;
- Excellent thermal and acoustic insulation;
- Simplified design for easy maintenance and cleaning;
- High protection against external agents;
- 2 Year Warranty,
- Includes high efficiency circulating pump.

Especificações Técnicas


Technical data 25 32 40
No. Elements of the Body 3 4 5
Nominal Heating Power (kW/kcal/h) 25 / 21.500 32 / 27.500 40 / 34.386
Usable Thermal Power (%) 91 92,8 90,3
Type of Fuel Diesel Diesel Diesel
Temperature of Combustion Gases (ºC) 187 185 182
Pressure loss gas side (mbar) 0,31-0,46 0,42-0,59 0,61-0,89
Total Volume Smoke Circuit (m³) 0,024 0,033 0,043
Combustion Chamber Diameter Depth (mm) 290 / 280 290 / 380 290 / 480
Combustion Chamber (Volume) (m³) 0,017 0,023 0,030
Burner Ecoflam Ecoflam Ecoflam
HYDRAULIC DATA
Primary Circuit Fluid Water Anti-Corrosive and Anti-Freeze Water Anti-Corrosive and Anti-Freeze Water Anti-Corrosive and Anti-Freeze
Temperature in the Primary Circuit (ºC) 70-90 70-90 70-90
Activation Temperature of the Safety Thermostat (ºC) 100 100 100
Maximum Pressure in the Primary Circuit (bar) 3 3 3
Body Test Pressure (bar) 5,2 5,2 5,2
Loss of Load in the Primary Circuit (mbar) 1,5 1,8 2,2
Water Volume (lts) 13,74 17,38 21,02
DHW PRODUCTION
Continuous Production of DHWAQS ∆T=30ºC (lts/min) 12 15 19
Maximum Pressure DHW (bar) 6 6 6
SIZE AND WEIGHT
Height (mm) 920 920 920
Depth (mm) 700 800 950
Width (mm) 520 520 520
Weight (kg) 165 195 225
ELECTRICAL DATA
Power Supply (V/Hz/F) 230/50/1~ 230/50/1~ 230/50/1~
EXHAUST AND VENTILATION
Diameter Smoke Exit (mm)(mm) 130 130 150
Minimum Diameter (mm) 150 150 175
Minimum Height (m) > 5 > 5 > 5
Diameter of Air Admission (cm²) > 213 > 279 > 348